ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ Π²Π»ΠΈΡΠ½ΠΈΡ ΡΠ»Π΅ΠΊΡΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΏΠΎΠ»Ρ, Π΄Π°Π²Π»Π΅Π½ΠΈΡ ΠΈ Π³Π΅ΠΎΠΌΠ΅ΡΡΠΈΠΈ ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ ΡΡΠ°ΠΊΡΠ° Π½Π° ΡΡΠ²ΡΡΠ²ΠΈΡΠ΅Π»ΡΠ½ΠΎΡΡΡ ΠΈ ΡΠ°Π·ΡΠ΅ΡΠ°ΡΡΡΡ ΡΠΏΠΎΡΠΎΠ±Π½ΠΎΡΡΡ ΡΠ°Π½Π΄Π΅ΠΌΠ°-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ ΠΏΡΠΈΡΠ°ΡΠ΅Π½ΠΈΡ ΠΈΠΎΠ½Π½ΠΎΠΉ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ/ΠΌΠ°ΡΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ
ΠΠΈΡΡΠ΅ΡΡΠ°ΡΠΈΡ
Π¨ΠΈΡΠΎΠΊΠΎΠ΅ ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΡ ΠΏΡΠΈΡΠ°ΡΠ΅Π½ΠΈΡ ΠΈΠΎΠ½Π½ΠΎΠΉ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ Π½Π°ΡΠ»Π° ΠΊΠ°ΠΊ ΠΏΡΠ΅Π΄Π²Π°ΡΠΈΡΠ΅Π»ΡΠ½ΡΠΉ ΡΠΈΠ»ΡΡΡ ΠΈΠΎΠ½ΠΎΠ² Π² ΠΌΠ°ΡΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΠΈ Ρ ΠΈΠΎΠ½ΠΈΠ·Π°ΡΠΈΠ΅ΠΉ ΠΏΡΠΈ Π°ΡΠΌΠΎΡΡΠ΅ΡΠ½ΠΎΠΌ Π΄Π°Π²Π»Π΅Π½ΠΈΠΈ. ΠΠ΅ΡΠΌΠΎΡΡΡ Π½Π° Π΄ΠΎΠ²ΠΎΠ»ΡΠ½ΠΎ ΡΠΊΡΠΎΠΌΠ½ΡΡ ΡΠ°Π·ΡΠ΅ΡΠ°ΡΡΡΡ ΡΠΏΠΎΡΠΎΠ±Π½ΠΎΡΡΡ Π‘ΠΠΠ (ΠΏΠΎ ΡΡΠ°Π²Π½Π΅Π½ΠΈΡ Ρ Ρ ΡΠΎΠΌΠ°ΡΠΎΠ³ΡΠ°ΡΠΎΠΌ), ΠΎΡΡΠΎΠ³ΠΎΠ½Π°Π»ΡΠ½ΠΎΡΡΡ ΡΠ°Π·Π΄Π΅Π»Π΅Π½ΠΈΡ Π°Π½Π°Π»ΠΈΡΠΎΠ² Π² Π‘ΠΠΠ ΠΈ ΠΌΠ°ΡΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ΅, ΠΎΡΠ½ΠΎΡΠΈΡΠ΅Π»ΡΠ½Π°Ρ ΠΏΡΠΎΡΡΠΎΡΠ° ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΡ ΠΈ Π½Π΅ΠΏΡΠΈΠ½ΡΠΆΠ΄Π΅Π½Π½ΠΎΡΡΡ ΡΡΡΠΊΠΎΠ²ΠΊΠΈ Π‘ΠΠΠ… Π§ΠΈΡΠ°ΡΡ Π΅ΡΡ >
Π‘ΠΏΠΈΡΠΎΠΊ Π»ΠΈΡΠ΅ΡΠ°ΡΡΡΡ
- ΠΠΎΡΡΠΊΠΎΠ² Π.Π. Ρ.966 583 Π‘Π‘Π‘Π // Π.Π. 1982. — № 38. (Π.Π . Gorshkov. Patent of
- USSR,# 966 583 (1982).) ! :
- ΠΡΡΡΠΊΠΎΠ² Π. Π., ΠΡΡΠ»ΠΎΠ² Π. Π., ΠΠ°ΠΊΠ°ΡΡ Π. Π., ΠΠ°Π·Π°ΡΠΎΠ² Π. Π., ΠΠ΅ΡΠ²ΡΡ ΠΈΠ½ Π. Π.,
- Π Π°ΡΡΠ»Π΅Π² Π£. X. Π Π°Π·Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΠΈΠΎΠ½ΠΎΠ² ΠΏΠΎ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ Π² ΡΠΈΠ»ΡΠ½ΡΡ ΠΏΠ΅ΡΠ΅ΠΌΠ΅Π½Π½ΡΡ ΡΠ»Π΅ΠΊΡΡΠΈΡΠ΅ΡΠΊΠΈΡ ΠΏΠΎΠ»Ρ.!! ΠΠΈΡΡΠΌΠ° Π² ΠΠ’Π€. — 1991. Π’.17, — № 12. — Ρ.60 — 65.
- ΠΡΡΡΠΊΠΎΠ² Π. Π., ΠΡΡΠ»ΠΎΠ² Π. Π., ΠΠ°ΠΊΠ°ΡΡ Π. Π., ΠΠ°Π·Π°ΡΠΎΠ² Π. Π., ΠΠ΅ΡΠ²ΡΡ ΠΈΠ½ Π. Π.,
- Π Π°ΡΡΠ»Π΅Π² Π£. X. ΠΡΠ΅ΠΉΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡ Π΄Π»Ρ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ»Π΅Π΄ΠΎΠ²ΡΡ ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ² Π°ΠΌΠΈΠ½ΠΎΠ² Π² Π°ΡΠΌΠΎΡΡΠ΅ΡΠ΅ Π²ΠΎΠ·Π΄ΡΡ Π° J7 ΠΠΠ₯. 1993. — Π’. 48, — № 1, — Ρ. 156 — 165.
- ΠΡΡΡΠΊΠΎΠ² Π. Π., ΠΡΡΠ»ΠΎΠ² Π. Π., Π‘ΠΎΠ»Π΄Π°ΡΠΎΠ² Π. Π. ΠΠ°ΡΠ΅Π½Ρ Π Π€ № 1 485 808, ΠΠΠ G 01 N27/62. Π‘ΠΏΠΎΡΠΎΠ± Π°Π½Π°Π»ΠΈΠ·Π° ΠΌΠΈΠΊΡΠΎΠΏΡΠΈΠΌΠ΅ΡΠ΅ΠΉ Π²Π΅ΡΠ΅ΡΡΠ² Π² Π³Π°Π·Π°Ρ ./I ΠΠ°ΡΠ². 30.03.87. ΠΠΏΡΠ±. 08.02.89.
- Carnahan Π. L., Tarassov A.S. US Patent #5 420 424.// 1995 (Ion Mobility1. Spectrometer).
- Kudryavtsev A., Makas A. Ion Focusing in a Ion Mobility Spectrometer (IMIS) with
- Eiceman G. A., Tarassov A., Funk P. A, Hughs S. E., Nazarov E. G., Miller R. A.
- Discrimination of Combustion Fuel Sources Using Gas Chromatography-Planar Field Asymmetric Waveform Ion Mobility Spectrometry./I J. Sep. Sci. — 26 (2003), -p. 585 -593.
- Gabryelski W., Wu F. and Froese K. L. Comparison of High-Field Asymmetric
- Waveform Ion Mobility Spectrometry with GC Methods in Analysis of Haloacetic Acids in Drinking Water.// Anal. Chem. 75 (2003), — p.2478 — 2486. i ,
- Buryakov I. A. Express Analysis of Explosives, Chemical Warfare Agents and Drugswith Multicapillary Column Gas Chromatography and Ion Mobility Increment Spectrometry Π J. Chromatogr. B, 800, — 2004, — p.75 — 82.
- R. W. Purves. D. A. Barnett, R. Guevremont. Separation of Protein Conformers
- Using Electrospray-High Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry.!I Int. Jour, of Mass Spectrom. 197 (2000), — p.163 — 177.
- R. W. Purves. D. A. Barnett, R. Guevremont., J. Vandermey. Analysis of a Tryptic
- Digest of Pig Hemoglobin Using ESI-FAIMS-MS.// Anal. Chem. 72 (2000), -p.4577 — 4584.
- Buryakov I. A. Ion Current Amplitude and Resolution of Ion Mobility Increment Spectrometer (IMS).// International Journal of Ion Mobility Spectrometry. 4(2) (2001),-p.l 12−116.
- Nazarov E. G., Miller R. A., Eiceman G. A., Krylov E., Tadjikov B. Effect of the Electric Field Strehgth, Drift Gas Flow Rate, and Temperature on RF IMS Response.// International Journal of Ion Mobility Spectrometry. 4(2) (2001), — p.43 -46.
- McCooeye M., Ding L., Gardner G. J., Fraser C. A., Lam J., Sturgeon R., Z. Mester.
- McCooeye M. A., Mester Z., Ells B., Barnett D. A., Purves R. W., Guevremont R.
- Handy R., Barnett D. A., Purves R. W., Horlick G., Guevremont R. Determination ofnanomolar levels of perchlorate in water by ESI-FAIMS-MSJ7 J. Anal. At. Spectrom.- 15 (2000),-p.907−911.18
- Buryakov I. A., Kolomiets Yu. N., Louppou V. Π. Ion Non-linear Drift Spectrometer
- LDS) a Selective Detector for High-Speed Gas Chromatography J I International Journal of Ion Mobility Spectrometry. — 4(1) (2001), — p. 13 — 15.
- Purves R. W., Guevremont R. Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass SpectrometryJ7 Anal. Chem. — 71 (1999),-p.2346−2357.22
- ΠΠ°Π½Π½ΡΡ Π. Π., ΠΠΎΠ²Π°ΡΠΎΠ²Π° Π. Π., ΠΠ°ΠΏΡΡΡΠΈΠ½ Π. Π. ΠΠΎΠ²ΡΠΉ ΠΏΠΎΠ΄Ρ ΠΎΠ΄ ΠΊ ΠΏΠΎΠ²Π΅ΡΡ Π½ΠΎΡΡΠ½ΠΎΠΉ ΠΈΠΎΠ½ΠΈΠ·Π°ΡΠΈΠΈ ΠΈ Π΄ΡΠ΅ΠΉΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠΈΠΈ ΠΎΡΠ³Π°Π½ΠΈΡΠ΅ΡΠΊΠΈΡ ΠΌΠΎΠ»Π΅ΠΊΡΠ» J7 ΠΠ’Π€. 72(12) (2002), — Ρ. 88 — 93.23
- ΠΡΡΠ»ΠΎΠ² Π. Π. ΠΠ°Π·ΠΎΡΠ°Π·ΡΡΠ΄Π½ΡΠΉ ΠΈΠΎΠ½ΠΈΠ·Π°ΡΠΎΡ Π² Π°ΡΠ³ΠΎΠ½ΠΎΠ²ΠΎΠΌ ΠΈΠΎΠ½ΠΈΠ·Π°ΡΠΈΠΎΠ½Π½ΠΎΠΌ Π΄Π΅ΡΠ΅ΠΊΡΠΎΡΠ΅.// ΠΠ’Π€. 70(11) (2000), -Ρ.126 — 132.
- Miller R., Nazarov Π., Eiceman G., Π’. King. A MEMS radio-frequency ion mobilityspectrometer for chemical vapor detection./7 Sencors and Actuators. — A 91 (2001), -p.307−318
- ΠΡΡΠ»ΠΎΠ² E. Π. Π‘ΠΏΠΎΡΠΎΠ± ΡΠΌΠ΅Π½ΡΡΠ΅Π½ΠΈΡ Π΄ΠΈΡΡΡΠ·ΠΈΠΎΠ½Π½ΡΡ ΠΏΠΎΡΠ΅ΡΡ Π² 'Π΄ΡΠ΅ΠΉΡ-ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ΅.// ΠΠ’Π€. 69(1) (1999), — Ρ. 124 — 127.
- Krylov Π. V. Comparison of the Planar and Coaxial Field Asymmetrical Waveform Ion Mobility Spectrometer (FAIMS)JI Int. Jour, of Mass Spectrom. 225 (2003), -p.39−51.97
- ΠΡΡΡΠΊΠΎΠ² Π. Π. ΠΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΠΊΠΈΠ½Π΅ΡΠΈΡΠ΅ΡΠΊΠΈΡ ΠΊΠΎΡΡΡΠΈΡΠΈΠ΅Π½ΡΠΎΠ² ΠΏΠ΅ΡΠ΅Π½ΠΎΡΠ° ΠΈΠΎΠ½ΠΎΠ² Π² Π²ΠΎΠ·Π΄ΡΡ Π΅ ΠΊΠ°ΠΊ ΡΡΠ½ΠΊΡΠΈΠΉ Π½Π°ΠΏΡΡΠΆΠ΅Π½Π½ΠΎΡΡΠΈ ΡΠ»Π΅ΠΊΡΡΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΏΠΎΠ»Ρ ΠΈ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ./7 ΠΠ’Π€. 74 (8) (2004), — Ρ. 15 — 20.
- ΠΡΡΡΠΊΠΎΠ² Π. Π. Π Π΅ΡΠ΅Π½ΠΈΠ΅ ΡΡΠ°Π²Π½Π΅Π½ΠΈΡ Π½Π΅ΠΏΡΠ΅ΡΡΠ²Π½ΠΎΡΡΠΈ Π΄Π»Ρ ΠΈΠΎΠ½ΠΎΠ² Π² Π³Π°Π·Π΅ ΠΏΡΠΈ ΠΈΡ Π΄Π²ΠΈΠΆΠ΅Π½ΠΈΠΈ Π² Π·Π½Π°ΠΊΠΎΠΏΠ΅ΡΠ΅ΠΌΠ΅Π½Π½ΠΎΠΌ ΠΏΠ΅ΡΠΈΠΎΠ΄ΠΈΡΠ΅ΡΠΊΠΎΠΌ, Π½Π΅ΡΠΈΠΌΠΌΠ΅ΡΡΠΈΡΠ½ΠΎΠΌ ΠΏΠΎ ΠΏΠΎΠ»ΡΡΠ½ΠΎΡΡΠΈ ΡΠ»Π΅ΠΊΡΡΠΈΡΠ΅ΡΠΊΠΎΠΌ ΠΏΠΎΠ»Π΅.// ΠΠΠ’Π€. 32(2), — 2006, — Ρ. 39 — 44.29
- Spangler G. Π. Relationships for Ion Dispersion in Ion Mobility Spectrometry Π International Journal of Mobility Spectrometry. 4(1), — 2001, — p.71 — 74. j, 30
- Spangler G. E., Miller R. A. Application of Mobility Theory to the Interpretation of Data Generated by Linear and RF Excited Ion Mobility Spectrometers./7 International Journal of Mass Spectrometry. 214, — 2002, — p.95 — 104.
- Nikolaev E. N., Vedenov A. A., Vedenova I. A. The Theory of FAIMS in Coaxial
- Cylinders Configuration.// Proceedings of the 52nd ASMS Conference on Mass Spectrometry and Allied Topics, Nashville, TN, USA, May 2004.
- ΠΠ΅ΡΠ²ΡΡ ΠΈΠ½ Π.Π., Π¨Π΅Π²Π΅Π½Ρ Π. Π. «ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠ² ΠΏΠΎΠ΄Π°Π²Π»Π΅Π½ΠΈΡ Π²Π»ΠΈΡΠ½ΠΈΡ ΠΎΠ±Π»Π°ΠΊΠ°Π·Π°ΡΡΠ΄ΠΎΠ² Π² ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ΅ ΠΏΡΠΈΡΠ°ΡΠ΅Π½ΠΈΡ ΠΈΠΎΠ½Π½ΠΎΠΉ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ ΠΊΠ°ΠΊ ΡΠΏΠΎΡΠΎΠ±Π° ΡΠ²Π΅Π»ΠΈΡΠ΅Π½ΠΈΡ Π΅Π³ΠΎ ΡΡΠ²ΡΡΠ²ΠΈΡΠ΅Π»ΡΠ½ΠΎΡΡΠΈ», // ΠΠ’Π€. 2008 — Π’.78, — ΠΡΠΏ.1, — Ρ. 114 -120.
- ΠΠ΅ΡΠ²ΡΡ ΠΈΠ½ Π.Π., Π¨Π΅Π²Π΅Π½Ρ Π. Π. «Π£Π²Π΅Π»ΠΈΡΠ΅Π½ΠΈΠ΅ ΡΠ°Π·ΡΠ΅ΡΠ΅Π½ΠΈΡ ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ° ΠΏΡΠΈΡΠ°ΡΠ΅Π½ΠΈΡ ΠΈΠΎΠ½Π½ΠΎΠΉ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ ΠΏΡΠΈ ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠΈ Π½Π°ΠΏΡΡΠΆΠ΅Π½ΠΈΡ <οΏ½ΡΡΠ±ΠΈ>», Π ΠΠΈΡΡΠΌΠ° Π² ΠΠ’Π€. 2008. — Π’.34, — ΠΡΠΏ.22. — Ρ.57 — 63.
- Pervukhin Viktor V., Sheven Dmitriy G. «Ion Peak Narrowing by Applyingi
- Additional AC Voltage (Ripple Voltage) to FAIMS Outlet Electrode» J I J Am Soc Mass Spectrom. 2010, — 21, — p.47 — 52. Ρ
- Shvartsburg A. Differential Ion Mobility Spectrometry. Nonlinear Ion Transport and Fundamentals of FAIMS. 11 International Standart Book Number-13: 978−1-4200−5106−32 009,-p.155 160.
- Guevremont R., High-field asymmetric waveform ion mobility: a new tool for mass spectrometry. il Rev. J. Chromatogr. A, 2004, — p.3 — 19.
- Mason E.A., McDaniel E.W., Transport Properties of Ions in Gases. ll Wiley, New York, 1988,-p.478.
- Ellis, H. W.- Pai, R. Y.- McDaniel, E. W.- Mason, E. A.- Viehland, L. A. At. Data Nucl. Data Tables.!! -1976, 17, — p.177 — 210.
- Viehland, L. A.- Mason, E. A. At. Data Nucl. Data Tables! I 1995, — 60, — p.37 — 95.
- McDaniel, E. W., Mason E. A. In The Mobility and Diffusion of Ions in GasesII Wiley: New York, — 1973,-p. 372
- Mason, E. A. In Plasma Chromatography!/Plenum Press: New York, 1984, -chapter 2,-p.49.
- Wannier, G. H. BellSyst. Tech.M. 1953, — 32, — 170.
- Krylova, N.- Krylov, E.- Stone, J. A.- Eiceman, G. A «Effect of Moisture on Highi ,
- Field Dependence of Mobility for Gas Phase Ions at Atmospheric Pressure: Organophosphorus Compounds"J/ J. Phys. Chem. 2003, — 107.
- Ferrara, P.- Apostolakis, J.- Caflisch, A. Thermodynamics and kinetics of folding oftwo model peptides investigated by molecular dynamics simulations.// J. Phys. Chem. B 2000, — 104, — 5000.
- Kim, H.- Kim, I. H.- Beegle, L. W.- Johnson, P. V.- Beauchamp, J. L. Theoretical Ion
- Mobility Studies of Amino Acids. ll Lunar and Planetary Science Conference XXXVII, Lunar and Planetary Institute, Houston, TX, 2006- - Abstract 2127.
- Guevremont R., Purves R., Barnett D., Ding L. Ion trapping at atmospheric pressure (760 Torr) and room temperature with a high-field asymmetric waveform ion mobility spectrometer. //Int. Jornal of Mass Spectrometry, 1999, — 193, — p. 45−56.
- Ellis H. W, McDaniel E.W., Albritton D.L., Viehland L.A., Lin S.L., Mason E.A., At.
- Data Nucl. Data Tables!/ 22 (1978), — p. 179.
- Ellis H.W., Thackston M.G., McDaniel E.W., Mason E.A., At. Data Nucl. Data Tables// -31 (1984), p. 113.
- Ells, B.- Barnett, D. A.- Purves, R. W.- Guevremont, R. Detection of Nine Chlorinated and Brominated Haloacetic Acids at Part-per-Trillion Levels Using ESI-FAIMS-MS.H Anal. Chem. 2000, — 72, — p.4555 — 4559.
- Shvartsburg, A. A.- Tang, K.- Smith, R. D. Optimization of the Design and OperationofFAIMS Analyzers.// J. Am. Soc. Mass Spectrom. 2005, — 16, — p. 1447 — 1455.
- Buryakov, I. A. Coefficient of Ion Mobility Versus Electric Field Strength Dependence in Gases: Experimental Determination.// Tech. Phys. 2002, — 47, -p.1453−1457.
- Buryakov, I. A. Determination of Kinetic Transport Coefficients for Ions in Air as Functions of Electric Field and Temperature.// Tech. Phys. 2004, — 49, — p.967 -972.
- Buryakov, I. A. Qualitative Analysis of Trace Constituents by Ion Mobility Increment
- Spectrometer.// Talanta 2003, — 61, — p.369 — 375.
- Purves R.W., Guevremont R., Day S., Pipich C.W., M.S. Matyjaszczyk, Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer! I Rev. Sci. Instrum. 69 (1998), — p.4094.
- Kouznetsov V., Method of controlling and correcting an asymmetric waveform.!! US
- Patent 5, — 801, — 379 (1998).
- Krylov E., Method for separation and enrichment of isotopes in gaseous phase.!! Instrum. Exp. Tech. 40 (1997), — p.628.
- Krylov E., Nazarov E.G., Miller R.A., Tadjikov B., Eiceman G.A., Comparison of
- Emission Profiles of Volatile Organic Compounds from Cotton and Polypropylene at Elevated Temperature in Inert Gas and Air. H J. Phys. Chem. A 106 (2002), -p.5437 — 5444.
- Buryakov I.A., Express Analysis of Explosives, Chemical Warfare Agents and Drugswith Multicapillary Column Gas Chromatography and Ion Mobility Increment Spectrometry./! J. Chromatogr. -B 800 (2004), p.75−82.
- Guevremont R., Barnett D.A., Purves R.W., Viehland L.A., Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry./7 J. Chem. Phys. 114 (2001),-p. 170.63
- Guevremont R., Purves R.W., Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer./7 Rev. Sci. Instrum. 70 (1999), -p.1370−83.
- Krylov E.V., A method of reducing diffusion losses in a drift spectrometer./7 Tech. Phys.-44 (1999),-p. 113.6V
- Mason E.A., McDaniel E.W. Transport Properties of Ions in Gases.// New York: Wiley, 1988, — p.558.
- Guevremont Roger, Purves Randy W., Barnett David A., Ding Luyi. Atmospheric Pressure Ion Trapping in a Tandem FAIMS-FAIMS Coupled to a TOFM: Studies with
- Electrospray Generated Gramicidin S Ions. I7 J Am Soc Mass Spectrom. 2001, — 12, -p.1320- 1330.
- Shvartsburg, A. A.- Tang, K.- Smith, R. D. Modeling the Resolution and Sensitivity of
- FAIMS Analyses J I J. Am. Soc. Mass Spectrom. 2004, — 15, — p.1487 — 1498.
- Shvartsburg, A. A.- Tang, K.- Smith, R. D. Optimization of the Design and Operationof FAIMS Analyzers. lI J. Am. Soc. Mass Spectrom. 2005, — 16, — p.2 — 12.
- Shvartsburg, A. A.- Tang, K.- Smith, R. D. Understanding and Designing Field Asymmetric Waveform Ion Mobility Spectrometry Separations in Gas Mixtures.// Anal. Chem. 2004, — 76, — p.7366 — 7374.
- Shvartsburg, A. A.- Tang, K.- Smith, R. D. FAIMS Operation for Realistic Gas Flow
- Profile and Asymmetric Waveforms Including Electronic Noise and Ripple.// J Am Soc Mass Spectrom. 2005, — 16, — p. 1447 — 1455.1. TX
- Sharp B.L., Sulaiman A.B., Taylor K.A., Green B.N., Observations on the use of Ion
- Spray Mass Spectroscopy for Elemental Speciation in Aqueous Solutions Without Recourse to Chromatography.// J. Anal. At. Spectrom. 12 (1997), — p.603.77
- Barnett A., Purves R.W., Guevremont R., Isotope separation using high-field asymmetric waveform ion mobility spectrometry. // Appl. Spectrosc. 53 (1999), -p.1367.
- Ells B., Barnett D.A., Purves R.W., Guevremont R., Trace level determination of perchlorate in water matrices and human urine using ESI-FAIMS-MS.// J. Environ. Monit. 2 (2000), — p.393.
- Purves R.W., Guevremont R., Electrospray Ionization High-Field Asymmetric Waveform Ion Mobilbity Spectrometry-Mass Spectrometry.// Anal. Chem. 71 (1999), — p.2346.
- Ells B., Barnett D.A., Froese K., Purves R.W., Hrudey S., Guevremont R.,// Anal.
- Chem. 71 (1999), — p.4747.
- Handy R., Barnett D.A., Purves R.W., Horlick G., Guevremont R. Determination ofnanomolar levels of perchlorate in water by ESI-FAIMS-MS.II J. Anal. At. Spectrom. 2000.-№ 15,-p.907−911.
- Guevremont R., Purves R.W., High field asymmetric waveform ion mobility spectrometry—mass spectrometry: an investigation of leucine enkephalin ions produced by electrospray ionization. II J. Am. Soc. Mass Spectrom. 10 (1999), -p.492.
- Guevremont R., Barnett D.A., Purves R.W., Vandermey J., Analysis of a Tryptic Digest of Pig Hemoglobin Using ESI-FAIMS-MS.il Anal. Chem. 72 (2000), -p.4577.
- D.A. Barnett, L. Ding, B. Ells, R.W. Purves, R. Guevremont, Application of ESI-FAIMS-MS to the analysis of tryptic peptides. ll Rapid Commun. Mass Spectrom. 16 (2002), — p.676.
- Barnett D.A., Ells B., Guevremont R., Purves R.W., Application of ESI-F AIMS-MS toi, the analysis of tryptic peptides. ll J. Am. Soc. Mass Spectrom. 13 (2002), — p. 1282.
- Purves R.W., Barnett D.A., Ells B., Guevremont R., Elongated Conformers of Charge
- States +11 to +15 of Bovine Ubiquitin Studied Using ESI-FAIMS-MS.il J. Am. Soc. Mass Spectrom. 12 (2001), -p.894.89
- Douglas D.J., An aerodynamic drag model for protein ions. ll J. Am. Soc. Mass Spectrom. 5 (1994), — p.17.
- Covey T., Douglas D.J., Collision cross section for protein ions. ll J. Am. Soc. Mass
- Spectrom. 4 (1993), — p.616.
- Monographs on the Evaluation of Caecinogenic Risks to Humans',// International Agency for Research on Cancer (IARC): Lyon, 1994- - Vol. 60, — p.389 — 433.
- Guidelines for drinking water quality, World Health Organization (WHO).// Vol. 1:
- Recommendations, 2nd ed.- WHO: Geneva, — 1993- - p.72.
- Zhang, Y.- Zhang, G. Y.- Yiping, R., New Research Developments on Acrylamide: Analytical Chemistry, Formation Mechanism, and Mitigation Recipes.// Chromatogr., -A 2005, — 1075,-p.l -21.
- Acrylamide by gas chromatography-// Method 8032A- U.S. EPA: Washinton, DC, 1996.
- Acrylamide, acrylonitrile and acrolein by high performance liquid chromatography
- HPLC)j! Method 8316- U.S. EPA: Washinton, DC, 1994.
- Taeymans, D.- Wood, J.- Ashby, P.- Blank, I.- Studer, A.- Stadler, R. H.- Gonde, P.-
- Marin, J., Pozo, O., Pitarch, E., Study of different atmospheric-pressure interfaces for1.-MS/MS determination of acrylamide in water at sub-ppb levels.// J. Mass spectrum. 2006- 41, — p. 1041 — 1048.
- Cheng Ka-Wing, Shi Jian-Jun Ou, Shi-Yi, Wang Mingfu, Jiang Yue. Effects of Fridt Extracts on the Formation of Acrylamide in Model Reactions and Fried Potato Crisps.// J, Agric. Food Chem. 2010, — 58, — p.309 — 312.
- Shaogang Chu and Chris D. Metcalfe., Analysis of Acrylamide in Water Using a Coevaporation Preparative Step and Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry. II Anal. Chem., 2007, — 79 (13), — p.5093 — 5096
- Pervukhin V., Ibragimov R., Moralev V. Mass Spectrometer Based on the MX-703A Analyzer with Direct Ion Injection from the Atmosphere. il Instruments and Experimental Techniques, Vol.40, — № 5, — 1997, — p. 122 — 124
- Vautz W., Sielemann S., Baumbach J. I. The influence of humidity on the determination of organic trace substances in ambient air using UV ion mobility spectrometry: alpha- and beta- pinene, 3-carene and limonene. ll IJIMS 6, 2003, -Vol.1,-p.21−29
- ΠΠ΅ΡΠ²ΡΡ ΠΈΠ½ Π., ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΠ΅ Π²Π»ΠΈΡΠ½ΠΈΡ ΠΏΡΠΈΠΌΠ΅ΡΠ΅ΠΉ Π² ΡΡΠ°Π½ΡΠΏΠΎΡΡΠ½ΠΎΠΌ Π³Π°Π·Π΅ Π½Π° ΠΏΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠ΅ ΠΈΠΎΠ½ΠΎΠ² Π² ΡΠΏΠ΅ΠΊΡΡΠΎΠΌΠ΅ΡΡΠ΅ ΠΏΡΠΈΡΠ°ΡΠ΅Π½ΠΈΡ ΠΈΠΎΠ½Π½ΠΎΠΉ ΠΏΠΎΠ΄Π²ΠΈΠΆΠ½ΠΎΡΡΠΈ.!I ΠΠΠ₯, — 2008, ΡΠΎΠΌ 63, — № 12, — Ρ. 1293 — 1301
- Dahl D. Π. // SIMION 3D Version 6.0 User’s Manual, 1995- http://citeseer.ist.psu.edu/article/dahl95users.html.