ΠΠΌΠΌΡΠ½ΠΎΠ°Π½Π°Π»ΠΈΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΌΠ΅ΡΠΎΠ΄Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΈΡΠΎΠΊΡΠΈΠ½Π° Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ ΠΌΠΎΠ½ΠΎΠΊΠ»ΠΎΠ½Π°Π»ΡΠ½ΡΡ Π°Π½ΡΠΈΡΠ΅Π»
Π’Π΅ΠΌΠ° Π΄ΠΈΡΡΠ΅ΡΡΠ°ΡΠΈΠΎΠ½Π½ΠΎΠΉ ΡΠ°Π±ΠΎΡΡ ΡΠ²Π»ΡΠ΅ΡΡΡ ΡΠ΅ΠΌΠΎΠΉ, ΡΡΠ²Π΅ΡΠΆΠ΄Π΅Π½Π½ΠΎΠΉ ΠΈ ΡΠΈΠ½Π°Π½ΡΠΈΡΠΎΠ²Π°Π²ΡΠ΅ΠΉΡΡ ΠΠΈΠ½ΠΈΡΡΠ΅ΡΡΡΠ²ΠΎΠΌ ΠΠ΄ΡΠ°Π²ΠΎΠΎΡ ΡΠ°Π½Π΅Π½ΠΈΡ ΠΈ ΠΠΈΠ½ΠΈΡΡΠ΅ΡΡΡΠ²ΠΎΠΌ ΠΏΠΎ Π§ΡΠ΅Π·Π²ΡΡΠ°ΠΉΠ½ΡΠΌ Π‘ΠΈΡΡΠ°ΡΠΈΡΠΌ «Π’4-Π’ΠΠ‘Π’». Π Π΄Π°Π½Π½ΠΎΠΉ ΡΠ°Π±ΠΎΡΠ΅ ΡΠΎΠ·Π΄Π°Π½Π° ΡΠ΅ΡΡ-ΡΠΈΡΡΠ΅ΠΌΠ° Π΄Π»Ρ ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²Π΅Π½Π½ΠΎΠ³ΠΎ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠ°ΡΠΈΠΈ ΡΠΈΡΠΎΠΊΡΠΈΠ½Π° Π² ΡΡΠ²ΠΎΡΠΎΡΠΊΠ΅ ΠΊΡΠΎΠ²ΠΈ Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ ΠΌΠΎΠ½ΠΎΠΊΠ»ΠΎΠ½Π°Π»ΡΠ½ΡΡ Π°Π½ΡΠΈΡΠ΅Π», ΠΊΠΎΡΠΎΡΠ°Ρ ΠΏΠΎΠ·Π²ΠΎΠ»ΡΠ΅Ρ ΠΏΡΠΎΠ²Π΅ΡΡΠΈ Π°Π½Π°Π»ΠΈΠ· Π·Π° 30 ΠΌΠΈΠ½ΡΡ, ΠΈΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΡ ΠΌΠ°Π»ΡΠΉ ΠΎΠ±ΡΠ΅ΠΌ ΠΊΡΠΎΠ²ΠΈ (Π΄ΠΎΡΡΠ°ΡΠΎΡΠ½ΠΎ Π±ΡΠ°ΡΡ… Π§ΠΈΡΠ°ΡΡ Π΅ΡΡ >
Π‘ΠΏΠΈΡΠΎΠΊ Π»ΠΈΡΠ΅ΡΠ°ΡΡΡΡ
- ΠΠ°Π»Π°Π±ΠΎΠ»ΠΊΠΈΠ½ Π.Π.// ΠΠ½Π΄ΠΎΠΊΡΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΡ. ΠΠΎΡΠΊΠ²Π°, ΠΠ΅Π΄ΠΈΡΠΈΠ½Π°, 1989.
- Π‘Π²ΠΈΡΠΈΠ΄ΠΎΠ² Π.Π.// Π‘ΡΡΡΠΊΡΡΡΠ½ΡΠ΅ ΠΈ ΡΡΠ½ΠΊΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΠ΅ Π°ΡΠΏΠ΅ΠΊΡΡ ΠΌΡΠ»ΡΡΠΈΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½ΡΠ½ΠΎΠΉ ΡΠΈΡΡΠ΅ΠΌΡ Π±Π΅Π»ΠΊΠΎΠ², ΡΠ²ΡΠ·ΡΠ²Π°ΡΡΠΈΡ ΡΠΈΡΠΎΠΊΡΠΈΠ½. ΠΠΈΠΎΡ ΠΈΠΌΠΈΡ, 1993, N 6, Ρ.57−62.
- Π‘ΡΠ°ΡΠΊΠΎΠ²Π° Π.Π’. //Π€Π°ΡΠΌΠ°ΠΊΠΎΡΠ΅ΡΠ°ΠΏΠΈΡ Π² ΡΠ½Π΄ΠΎΠΊΡΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΠΈ. ΠΠΎΡΠΊΠ²Π°, ΠΠ΅Π΄ΠΈΡΠΈΠ½Π°, 1989.
- Π’ΡΡΠ°ΠΊΡΠ»ΠΎΠ² Π―.Π₯. //ΠΡΡΠΈ Π±ΠΈΠΎΡΠΈΠ½ΡΠ΅Π·Π° ΠΈ ΠΌΠ΅Ρ Π°Π½ΠΈΠ·ΠΌ Π΄Π΅ΠΉΡΡΠ²ΠΈΡ Π³ΠΎΡΠΌΠΎΠ½ΠΎΠ²ΡΠΈΡΠΎΠ²ΠΈΠ΄Π½ΠΎΠΉ ΠΆΠ΅Π»Π΅Π·Ρ Π² Π½ΠΎΡΠΌΠ΅ ΠΈ ΠΏΠ°ΡΠΎΠ»ΠΎΠ³ΠΈΠΈ. ΠΠ΅ΡΡΠ½ΠΈΠΊ ΠΠΠ Π‘Π‘Π‘Π , 1988. N7, Ρ.54−61.
- Abuid J" A.H.Klein, Π’.Π . Foley, P.R.Larsen. // Total and freetriiodothyronine and thyroxine in early infancy. J. Clin. End. Metab. 1974. V.39. P.263−268.
- Anderson V.L. // Thyroid hormons alters the DNA binding properties ofchicken thyroid hormone receptors and Nucleik Acids Res. 1992. V.20. N.18. P.4803−4810.
- Aracava, Maeda, Tsuji, Ishii. //Fluorophotometric enzyme immunoassay of
- T4 in dried blood samples on filter paper. Bunseki Kagaki 1982, V.31, p.55−61.
- Beaman J., Woodhead J.S., Liewendahl K., MahonenH. // The evaluationof a chemiluminescent assay for free thyroxine by comparison with equilibrium dialysis in clinical samples. Clin.Chem. Acta. 1989., V.189., P.83−90.
- Beatty J.D., Beatty B.G., Vlahos W.G. // Measurement of monoclonalantibody by non-competitive enzyme immunoassay. J.Immunol.Meth., 1987, V.100, P.173−179.
- Belgorodsky. //Evaluation of serum total T4. J. Endocrin. Invest. 1993, V.7, p. 499−503.
- Bhagat C., Garcia-Webb P., Watson F., Beilby J. // Interference of radioimmunoassay of total serum thyroxine and free thyroxine due to thyroxine binding autoantibodies. Clin. Chem. 1983., V.29., P. 1324−1325.
- Bhayana V., Y.A.Tan, A. Papanastasiou-Diamandi, M.J.Khosravi // A one-step immunoassay free-T4 by time-resolved immunofluorometry. 1990., V.36. N.6., P.1077.
- Bianca C., D. Hwang, B. Meriadec, M. Strasswimmer, C.Woo.//An improved, second generation method for T4 on the Technicon RA System. 1990., Clin. Chem. V.36., N.6., P. 1082.
- Blick K.E., Michael Smith, Gillum R.L. // Apparent Lack of Concordance between Free T4 and TSH Determinations. Clin. Chem. 1991, V.37, N.6, P.943.
- Braverman L.E., Vagenakis A.G., Foster A.E., Ingbar S.H.// Evaluation of a simplified technique for the specific measurement of serum thyroxin concentration. J.Clin.Endoc. 1971, V.32, P.497−502.
- Buchman D., Miller D., Koch G.// Monoclonal antibodies to digoxin, comparison of an vitro and in vivo immunization Hybridoma 1985 V.4. P.173−177.
- Canova-Davis E., Redemann C.T., Volmer Y.P., Kung V.T.//Use of a reversed-phase evaporation vesicle formulation for a homogeneous liposome immunoassay Clin.Chem. 1986 V.32, P.1687−1691.
- Cernosek R.M., M. Klute, M. Norden, D. Ashby, and W. Knight / / An automated solid-phase enzyme immunoassay for measurement of T-Uptake. Clin.Chem. 1990, V.36, N.6, P.1079.
- Chang E.L., Waite B.A.// Analysis of vesicle immunolysis assays: the direct binding model J.Immun.Methods 1987 V.102, P.33−43.
- Chen I.W., Sohnlein B., Heminger L., Sperling M. // Evaluation of a fully automated immunoassay system for thyroid function testing. Clin.Chem. 1990, V.36, N.6, P. 1080.
- Chilcoat K.A., O Kell R., Shea R.A. // Evaluation of the SYVA EMIT thyroxine assay applied on the COBAS BIO. Clin.Chem.1990, V.36, N.6, P.1079.
- Chooi M.K., Coates J.E.// Effect of use of a specific monoclonal antibody on radioimmunoassay results for serum cyclosporine. Clin.Chem. 1988. V.34. P.2556.
- Churchill W.H., Tapley D.F. //Antibodies specific for thyroxine and its analogues. Nature 1964, N.202, P. 29−31.
- Cole R. and Trundle D.S.//Evaluation of SYVA ECP thyroxine and T-Uptake reagent on the COBAS FARA 11. Clin.Chem.1991,V. 37, N.6, P. 938.
- Collinsworth W.L. // Multicenter evaluation of CEDIA T4 and T-Uptake assays on Boehringer Mannheim/Hitachi Analyzers. Clin.Chem. 1990, V.36, N.6, P. 1078.
- Cristofides, Nicos, Sheehan. //Multicenter evaluation of enhanced chemiluminescence labeled-antibody immunoassay (Amerlite) for T4. Clin. Chem.1995, V. l, p. 24−31.
- De-Groot L.J. // Mechanism of thyroid hormone action. Adv. Exp.Med.Biol. 1991, V.299, P.l.
- Delange.// Neonatal hypothyroidism. Clin. Endocrin. 1988, V.2, p. 637−652.
- Desai R.K., Deppe W.M., Norman R.J. // The simple TRAC FT4 / TSH assay evaluated as first-line thyroid function test. Clin.Chem. 1988, V.34, P. 1488−1491.
- Diran, Riodan, Silbert. //Effect of hapten heterology on thyroid hormone immunoassays. JIM 1990, N 2, p. 207−214.
- Duffy P., Marshall C.M. // Performance of EMIT T4 and T-Uptake assays on the Technicon CHEM 1 ANALYSER. Clin.Chem. 1990, V.36, N.6, P. 1083.
- Engvall E., Perlmann P.// Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G, Immunochemistry 1971, V.8, P.871−874.
- Farid N.R., Kennedy C. // Assessment of a method of measuring serum thyroxine by radioimmunoassay, with use of polyethylene glycol precipitation. Clin.Chem. 1977, V.23, N.7, P. 1333−1335.
- Ferrua, Genetet, Savaron, Moulin, Salard, Massaeff./ / Immunoassay of total T4 using immobilizate antibody. JIM 1986, V.87, p. 137−143.
- Freytag J.W., Dickinson J.C., Tseng S.Y.// A highly sensitive * affinity-column-mediated immunometric assay, as exeplified bydigoxin. Clin.Chem. 1984 V.30, P.417−420.
- Gil, Tang, Halsall, Heineman, Misiego. //Competitive heterogeneous enzyme immunoassay for theophylline. Clin. Chem. 1990, V.36, p.662−665.
- Gonzales R. //An enzyme immunoassay for determination TT4 in human serum using an ultramicroanalitical system. Clin. Chem. Acta 1991, V.3, p. 159−170.
- Green G., Inbar S., Meneghini F.A., Long E.W., Yamartino E.J., Bo wen M.S., Blackwood J.J., Padila A.J., Maretsky D., Staedter //Multilayer fluorescent immunoassay technique. Clin.Chem.(1989) 35, 1865−1868.
- Greene H., Hwang D., Hutchins J., Johnson A. // Technicon thyroxine and thyroid binding globulin: two fully automated immunoassays for the serum. Clin. Chem. 1990, V.36, N.6, P. 1082.
- Guin, Witty. //Molecular film fluorescence technology applied to detection of T4. Clin. Chem. 1993, v.6, p. 1163.
- Hammila I.// Fluoroimmunoassays and immunofluorometric assays. Clin.Chem. 1985, V.31, P.359−370.
- Hammila I., Malminen O., Micola H., Lovgren T.// Homogeneous time-resolved fluoroimmunoassay of thyroxin in serum. Clin. Chem. 1988, V.34, p.2320−2322.
- Helemus T., Liewendahl K. // Improved dialysis method for free «thyroxin in serum compared with five commercialradioimmunoassays in nonthyroidal illness and subjects with abnormal concentration of TBG. Clin. Chem. 1983, V.29, N.5, P. 816−822.
- Helfand. //Screening for thyroid disfunction. JAMA 1993, V.270, p. 2297−2298.
- Hoffman W. //Characterization of immune complex components by dot blot analysis. Anal. Biochem. 1992, V. l, p.44−50.
- Hollander L., Worthy T.E. // Performance of the microgenics CEDIA T4 MAB and T-Uptake assays on the coulter electronics optichem. Clin.Chem. 1991, V.37.N. 6, P. 944.
- Hunter M.M., Margolies M.N., Ju A., Haber E. //High-affinity monoclonal antibodies to the cardiac glicozide digoxin. J.Immunol. 1982. V.129 P.1165−1172.
- Jarvis S., Socqueline A. // Homology model of thyroxine binding globulin and elucidation of the thyroid hormone binding site. Protein Eng. 1992, V.5, N. l, P. 61−67.
- Khosravi M.J. and A. Papanastasiou-Diamondi. // Hapten -heterologous conjugates evaluated for application to free thyroxine immunoassays. Clin.Chem. 1993, V.39, N.2.P.256−262.
- Kohler G., Howe S.C., Milstein C. //Fusion between immunoglobulin secreting and non-secreting myeloma cell lines. Eur. J. Immunol., 1976, V.6, P.292.
- Kruse V.// Production and evaluation of high-quality thyroxine antisera for use in radioimmunoassay. Scand.J. Clin. Lab. Invest. 1976, V36.P.95.
- Kwiatkowski M., Long L., and Sickel M. // An automated chemiluminescence immunoassay test for free thyroxine (FT4) Clin. Chem. 1990, V.36, N.6, P. 1078.
- Lenz, Helmet, Bialk (Boeringer Mannheim). //Method and standart solution for determination of T3 or T4 in serum by immunoassay. Patent DE 4,226,949. 1994.
- Leo-Mensah A., Piran Uri, Blick M., Edgeworth D., Hayes E., Simonaitis R., Hudson T. // An automated chemiluminescence immunoassay test for total thyroxine. Clin. Chem. 1991, V.3, p. 137−140.
- LeVinson S.S., Burch P.A. // Microparticle enzyme immunoassay (MEDYA) and fluorescence polarization (FP) for thyroid evaluation. Clin.Chem. 1991, V.37, N.6, P. 943.
- Litchfield W.J., Freytag J.W., Adamich M.// Highly sensitive immunoassays based on use of liposomes without complement Clin.Chem. 1984. V.30, P.1441−1445.
- Luckenbach C. et al. // Isoelectric focussing of human thyroxine binding globulin (thyropexin) and human prealbumin (transthyretin). Eur.J.Clin.Chem.Clin.Biochem., 1992, V.30, N.7, P. 387−390.
- Maeda Masaco, Hiroshi Ohokuma, Hidetochi Arakawa, and Akio Tsuji. / / Enzyme-linked immunosorbent assay for free thyroxin using glucose oxidase as a label enzyme. Clin. Chem., 1990, V.36, N. 6, P. 1078.
- Marsh J.A., Johnson B.E., Lillehoj H.S., Scanes C.G. // Effect of thyroxine and Chicken growth hormone on immune function in autoimmune-thyroiditis (Obese). Proc. of the society forexper.biol.and med., 1992, V.199, N. l, P. 114−122.
- Mitsuma T., Colcci J., Shenkman L., Hollander C.S. //Rapid simultaneous radioimmunoassay for triiodothyronine and thyroxine in unextracted serum. BBRC. 1972, V.46, N.6, P.2107- 2113.
- Mpoko C.N., Cordon D.B., Laing I., Corbitt G., Storey C.C. //The production and characterisation of a monoclonal antibody to thyroxin. Clin.Chem.Acta, 1985, V.146, P. 215−222.
- Murray R., Burkhardt M., Boches F. // Development of a monoclonal antibody based total T4 RIA. Clin.Chem., 1990, V.36, N.6, P. 1077.
- Nakane P.K., Kawaoi A. // Peroxidase labeled antibody a new method of conjugation. J. Histochem. Cytochem., 1974, V.72, P. 108.
- Nantov, Suonpaci, escola, Lovgren. //Direct solid-phase fluoroassay of TT4. J. Clin. Biochem. Science, 1985, V.4, p.52−56.
- Nelson J.C., Tomei R.T. // Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay. Clin.Chem., 1988, V.34, P. 1737−1744.
- Neto E.G., J. Schulte, E. Kreisner and R. Giugliani. // Application of a comprehensive protocol for detection and diagnosis of congenital hypothyroidism in Brazil.Clin.Chem. 1991, V.37., N.6, P.935.
- Nishokawa T., Kubo H., Saito M.// Competitive nephelometric immunoassay of theophylline in plasma. Clin. Chim. Acta 1979, V.91, P.59−65.
- Olberding M.L., Haven M.C., Markin R.S. //Evaluation of the reformulated TDx thyroxine assay. Clin. Chem. 1990, V.36, N.6, P. 1080.
- Ozinscas et all. //Homogeneous model immunoassay of T4 by phase-modulation fluorescence spectroscopy. Anal. Biochem. 1993, V.2, p. 264−270.
- Papanastasiou-Diamandi A., Bhayana V., Diamandis E.P. //A time resolved fluoroimmunoassay of total thyroxine in serum. Ann.Clin.Biochem. 1989, V.26., P.238.
- Plomp T.A., Drost R.A., Thyssen J.H.N. // Evaluation of the manual enzyme immunoassay (EMIT) procedure for the determination of serum thyroxin. J.Clin.Chem.Clin.Biochem. 1979, V.17, P.315.
- Pollack. //A fluorescence liposome immunoassay for TT4. Clin. Chem. 1993, V.6, p.1254.
- Ratcliffe W.A., Challand G.S., Ratcliffe J.G.,// A critical evaluation of separation methods in radioimmunoassay for total triiodothyronine and thyroxine in unextracted human serum. Ann. Clin. Biochem. 1974, V. ll, P.224.
- Ratcliffe W.A., Ratcliffe J.G., McBridge A.D.// The radioimmunoassay of thyroxine in unextracted serum. Clin. Endocrinol. 1974. V.3., P.481.
- Ritter D., Stott R., Grant N., Moon H. Nahm // Endogenous antibodies that interfere with thyroxine fluorescence polarization assay but not with radioimmunoassay or EMIT. Clin. Chem. 1993, V. 39, N.3, P.508−511.
- Robins B., Soltys R., Dowben R., Alford M., Shriver B. // Development of a fluorescence polarization immunoassay for total T4. Clin.Chem.1993. V.39/6.P.1169.
- Sapin R. // In vitro and in vivo effects of increased «concentrations of free fatty acids on free thyroxinmeasurements as determined by five assays. Clin.Chem. 1990, V.36, N.4, P.611−613.
- Sapin, Remy, Gasser, Francoise. //Spuriously high concentration of serum FT4 due to anti-T3 antibody. Clin. Chem. 1995, V. l, p. 117−118.
- Schmitt Cheril A. and A. A. McDonough. / / Thyroid hormone regulates and isoforms of Na, K — ATPase during development in neonatal rat brain. J.Biol.Chem. 1988, V.263, N.33, P. 176−178.
- Schroeder H.R., Yeager F.M., Boguslaski R.C., Vogelhut P.O. // Immunoassay for serum thyroxin monitored by chemiluminescence. J.Immunol. Methods, 1979, V.25, P.275−282.
- Sestoft L. //Metabolic aspects of the calorigenic effect of thyroid hormone in mammals. Clin.Endocrin., 1980, V.13,P.489
- Shall, Fraser, Hansen. //A sensitive manual enzyme immunoassays for T4. Clin. Chem. 1990, V.2, p. 933−938.
- Siebert G.R., Raleigh N.C., Armstrong J. // Monoclonal antibodies recognizing L-thyroxine. United States Patent 1989, N. 4,888,296.
- Sqoutas D., Annie Love, Fredricks M. // Comparison of the TOSOH AIA 1200, ABBOT TDx and Pharmacia DELFIA methods for the determination of serum thyroxine. Clin.Chem. 1991, V.37, N.6, P.942.
- Sturgess M.L., Ian Weeks, C.N. Mpoko. // Chemiluminescent labeled-antibody assay for thyroxin in serum, with magnetic separation of the solid phase. Clin.Chem., 1986, V.32, N.3, P.532−535.
- Surks M.I., Hupart K.H., Pan C. // Normal free thyroxine in critical nonthyroidal illnesses measured by ultrafiltration of undiluted serum and equilibrium dialysis. J.Clin.Endocrinol.Metab. 1988, V.67, P.1031−1039.
- Taimela, Aalto, Mijia.// Clinical laboratory studies of fluorescence immunoanalisis of TT4. Clin. Chem. 1993, V.4, p.679−682.
- Thede-Reynolds K.R., Johnson G.F. // Antibody suitability for two stage free thyroxin assay. Clin.Chem. 199,1, V.37, N.6, P. 1044.
- Tillotson, Lartic. //Plasma total Thyroxine. J. Clin. Pathology, 1992, V.9, p. 818−820.
- Tuuminen T., Kaepyaho K. // Determination of thyrotropin, thyroxine and free thyroxine in dried blood samples by enzyme FIA. Eur.Pat.App.EP 1991, N.460,650.
- Velasques, uphan, Philipp, Altaffer.// ELISA T4 assay compared to fluorescence polarisayion. Clin. Chem. 1993, V.39, p. 1209.
- Wallase, Aitken, Duffy, Fraser.// Measurement FT4 by using Magnetic Ab-containing Microcapsules. Clin.Chem. 1990, V74, p. 614−619.
- Wang</span> L., Hexter C.S., Inbar M. // Monoclonal antibodies to thyroid hormones anti-thyroxine and anti-triiodothyronine in
- Monoclonal antibodies and T cell Hybridomas. Eds: Hammerling G.I., Hammerling G.H., Kearney J.F. Elsevier, Amsterdam, 1982. P.357.
- Weerasecera, Kim, Barnard.// Measurement of T4 by solid phase chemiluminescence. Clin. Biochem. 1993, V. l, p. 100−104.
- Welby M. //Clinical chemistry of thuroid function testing. Adv. Clin. Chem. 1990, V.28, p. 81−92.
- Wilson M., Hitchcock K.R., De-Lellis R.A. // Immunohistochemical localization of thyroid hormone in rat thyroid gland. J. Histochem.Cytochem. 1978, V.26. P.1121.
- Yaoita Y., Brown D.D. // Xenopus laevis and thyroid hormone receptors. PNAS, 1990, V.87, P. 7090−7094.
- Yatscoff R.W., Hayter J.// Competitive nephelometric inhibition immunoassay of theophylline with use of monoclonal reagents: comparison with EMIT procedures -Clin.Chem. 1983. V.29, P. 1857−1858.
- Zuk, Rowky.// Flurescence protection: a new homogeneous assay technique. Clin. Chem. 1989, V.5, p. 1554−1560.